CO2 sensors KSC 122 with output RS 485 (MODBUS) are intended for installation in airconditioning ducts.
The sensor can be used for any control systems compatible with the output signal RS 485 (MOBDUS). The working range is specified in the table of technical parameters. The sensors meet the ingress protection of IP 65 according to ČSN EN 60 529..
The sensor can be used for any control systems compatible with the
MODBUS RTU communication protocol; communication takes place
through the RS 485 bus. The working range is specified in the table of
technical parameters. The sensors meet the ingress protection of IP 65
according to ČSN EN 60 529.
The sensors consist of a plastic head, which houses a transducer to convert the
CO2 concentration to a MODBUS RTU output signal. The measuring sensor is
located in an external probe which is firmly connected to the electronics head.
The probe cannot be disconnected from the head with electronics. The supply
cable is connected to the terminal board through a grommet, which is a part
of the plastic head. The base material of the head is LEXAN™ RESIN – EXL 5689.
The sensor stem consists of two materials – stainless steel and Tecaform. Sensor is
ensured by the unique „S head“ design invented by SENSIT s.r.o
The operating conditions to establish the correct function of CO2 modul are:
- Ambient temperature around the sensor: -40 °C to 80 °C
- Relative ambient humidity: 0 to 100 %
- Atmospheric pressure: 87 to 106 kPaTESTS, DECLARATION, CALIBRATIONS
TESTS, DECLARATION, CALIBRATIONS
The type tests are carried out by a notified body according to EN 50155 standard, as amended, Railway applications – Electronic equipment used on rolling stock.
- Electromagnetic Compatibility in accordance with EN 50121-3-2, as amended
- Insulation test in accordance with EN 50155, as amended
- Shock and vibration tests in accordance with EN 61373, as amended
The product meets parameters in accordance with EN 45545-2, as amended, Fire protection on railway vehicles - Part 2: Requirements for fire behavior of materials and components. Can be supplied with materials complying with fire safety standard NFPA 130, as amended.
- Manufacturer provides EU Declaration of Conformity.